Inspection Requirements by States

"A wire- or strand-wound prestressed tank should be inspected after the first year of service". . .and "routinely every 5 to 10 years following the initial inspection."
- ANSI/AWWA Standard D110-04 Wire- and Strand- Wound, Circular, Prestressed Concrete Water Tanks "Sec. 6.4 Inspection During Routine Maintenance"

Inspection
Alabama "All public water systems are to have their water storage tanks inspected at regular intervals."
ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT WATER DIVISION - WATER SUPPLY PROGRAM - DIVISION 335-7 REVISED EFFECTIVE: MAY 26, 2009
http://www.adem.state.al.us/Regulations/Div7/Div7Effective5-26-09.pdf (pg. 7-3)

Florida "Finished-drinking-water storage tanks. . . shall be cleaned at least once every five years. . . and shall be inspected for structural and coating integrity at least once every five years by personnel under the responsible charge of a professional engineer licensed in Florida."
https://www.flrules.org/gateway/RuleNo.asp?id=62-555.350

Georgia "All distribution storage facilities should be drained, cleaned, and inspected annually."
APPENDIX B, OPERATIONS & MAINTENANCE PLAN - Guidance Manual for Preparing Public Water Supply System O & M Plans. MAY, 2000 (Section 3.3; page 136; paragraph B)
http://www.gaepd.org/Files_PDF/techguide/wpb/o&m.pdf

Kentucky Researching - to be added.

Louisiana Researching - to be added.

Mississippi Researching - to be added.

North Carolina Researching - to be added.

South Carolina Researching - to be added.

Tennessee "Community Water Systems shall have a professional inspection performed and a written report produced on each of their finished water and distribution storage tanks at least once every five years. Non-community water systems shall have a professional inspection and written report performed on each of their atmospheric pressure finished water and distribution storage tanks no less frequently than every five years."
RULES OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION - BUREAU OF ENVIRONMENT - DIVISION OF WATER SUPPLY CHAPTER 1200-05-01- PUBLIC WATER SYSTEMS
http://tn.gov/sos/rules/1200/1200-05/1200-05-01.20090606.pdf (pg. 89)

Virginia Refer to AWWA Standards